ETA-for the use in concrete Fire Resistance in Concrete DIBt-approval -for the use in masonry Fire Resistance in Masonry  
  Injectionsystem for use in concrete and solid and perforated brickwork
  Injection System VMU zinc plated / hot dip galvanized
   
   
 
   


Description
The Injection System
VMU is a chemical fastening system with an European Technical Approval (ETA, Option 7) for the use in non-cracked concrete and a DIBt-Approval for the use in solid and perforated brickwork.
It consists of a styrene free vinyl ester resin in a cartridge to be used together with different kinds of threaded studs that can be chosen depending on the base material.The system also includes a perfo-sleeve for the use in perforated brickwork.
By means of the dispenser gun the two components of the adhesive are injected through the mixer nozzle into the perforated sleeve. The threaded stud or sleeve is inserted manually. The hardened injection adhesive gives a secure fastening to the base material.


Applications:
Medium to high duty anchorings in non-cracked concrete: base plates, wood structures, pallet racks
Light to medium duty anchorings into brickwork:: projecting roofs, window and door frames, claddings, wood structures.

 
 


Approved loads in concrete as per ETA-05/0253

non-cracked concrete, 50°C/80°C *

M8
M10
M12
M16
M20
M24

M30

Tension
app.N
C20/25
[kN]
7,6
11,9
16,7
23,8
45,2
54,8
81,0
   
C25/30
[kN]
8,1
12,6
17,7
25,2
48,0
58,0
85,8
   
C30/37
[kN]
8,5
13,3
18,7
26,7
50,7
61,3
90,7
   
C40/50
[kN]
8,6
13,8
20,0
29,3
55,6
67,4
99,6
   
C50/60
[kN]
8,6
13,8
20,0
31,0
58,6
71,2
105,2
Shear app.V
>C20/25
[kN]
5,1
8,6
12,0
22,3
34,9
50,3
80,0
Bending moment app.M
[Nm]
10,9
21,1
37,1
94,3
185,7
320,6
642,3
*Approved loads: total safety factor as per ETAG included.
Loads are valid for permanent temperatures up to 50°C and short term temperatures up to 80°C. Lower loads apply for reduced anchor spacings, edge distances and anchorage depths.
For anchor designing an easy to operate CD-ROM is available on request or download.

Approved loads in masonry for tension, shear and oblique tension
as per Z-21.3-1803
appr. F for M8-M12
 
drilling with hammer-action
drilling with rotation only
Spacing*
a
[mm]
Edge distance*
ar
[mm]
Solid brick (DIN 105)
Mz12
[kN]
1,7
1,7
100
250
Solid sand-lime brick (DIN 106)
KS 12
[kN]
1,7
1,7
100
250
Vertical perforated brick (DIN 105)
HLz 4
[kN]
0,3
0,6
100
200
 
HLz 6
[kN]
0,4
0,8
100
200
 
HLz 12
[kN]
0,8
1,0
100
200
Sand-lime perforated brick (DIN 106)
KSL 4
[kN]
0,4
0,6
100
200
 
KSL 6
[kN]
0,6
0,8
100
200
 
KSL 12
[kN]
0,8
1,4
100
200
Hollow block (concrete, DIN 18151)
Hbl 2
[kN]
0,3
0,5
200
200
 
Hbl 4
[kN]
0,6
0,8
200
200
Hollow block (concrete, DIN 18153)
Hbn4
[kN]
0,6
0,8
200
200

* Spacing and edge distance may be reduced to 50 mm (not valid for Hbl and Hbn brickwork)
Reduced loads can be calculated according to the approval.


Spacing and edge distance for the use in concrete

 
M8
M10
M12
M16
M20
M24

M30

Effective anchorage depth
hef
[mm]
80
90
110
125
170
210
270
Characteristic spacing
scr,N
[mm]
160
180
220
250
340
420
540
Characteristic edge distance
ccr,N
[mm]
80
90
110
125
170
210
270
Min. thickness of concrete
hmin
[mm]
100
130
160
200
220
280
350
Red. minimum thickness
red. hmin
[mm]
-
120
140
160
-
-
-
Min. spacing
smin
[mm]
40
45
55
65
85
105
135
Min. edge distance
cmin
[mm]
40
45
55
65
85
105
135


 


Spacing and edge distance for the use in masonry
 
M 8
M10
M 12
IG M6
IG M8
Effective anchorage depth
hef
[mm]
80
90
93
93
93
Char.spacing (anchor groups)*
a
[mm]
100 (200)**
Min. spacing (anchor groups)
amin
[mm]
50***
Min. spacing (single anchor)
az
[mm]
250
Char. edge distance
ar
[mm]
200 (250)****
Edge distance for special applications
ar
[mm]
50 (60)****
Min. thickness of base material
hmin
[mm]
110
* Spacing for anchor groups can be reduced to min. spacing. Loads can be calculated according to the approval. (Not valid for Hbl and Hbn brickwork).
** Values in brackets for Hbl (LB-Hollow-block concrete DIN 18151) und Hbn (Hollow-block concrete DIN 18151).
*** not valid for Hbl- und Hbn-brickwork
**** Value in brackets valid for solid brickwork only


Installation parameters for the use in concrete
     
M8
M10
M12
M16
M20
M24

M30

Drill hole diameter
do
[mm]
10
12
14
18
22
26
32
Diameter of clearance hole in the fixture
df
[mm]
9
12
14
18
22
26
33
Depth of drill hole
h0
[mm]
80
90
110
125
170
210
270
Installation torque
Tinst
[Nm]
10
20
40
60
120
150
300
Width across nut
SW
[mm]
13
17
19
24
30
36
46
Anchors/cartridge
300ml / 345ml
 
[pcs]
50/58
35/41
24/28
15/17
8/10
5/6
3/3,5



 

Installation in concrete:

     
             
     


Installation parameters for use in masonry
     
M 8
M 10
M 12
IG M6
IG M8
Diameter of drill hole with perfo-sleeve (hollow blocks)
do
[mm]]
14
16
16
16
16
Diameter of drill hole without perfo-sleeve (solid blocks)
do
[mm]]
10
12
14
12
14
Diameter of clearance hole in the fixture
df
[mm]
9
12
14
7
9
Depth of drill hole with perfo-sleeve (hollow blocks)
h0
[mm]]
105
Depthr of drill hole without perfo-sleeve (solid blocks)
h0
[mm]
85
95
98
98
98
Installation torque
Tinst
[Nm]
8
Holes / cartridge 345ml
with perfo-sleeve
[Stück]
20
14
14
14
14
Holes / cartridge 345ml
without perfo-sleeve
[Stück]
58
41
31
41
31


 


Installation in hollow brickwork:

     
             
     

Temperature of
base material
Gel time
[min]
Curing time in dry concrete
[min]
Curing time in wet concrete
[min]
+ 40 °C
1,4 15 30

+ 35 °C

2 20 40
+ 30 °C
4 25 50
+ 20 °C
6 45 90
+ 10 °C
12 80 160
+ 5 °C
20 120 240
0 °C
45 180 360
-5°C
90 330 660

Product Range

Threaded Studs VMU-A, for the use in concrete
steel, zinc plated/ hot dip galvanized

Description
Ref. No.
steel, zinc plated
Fixture thickness
[mm]
VMU-A 8-10/100
31510101
10
VMU-A 8-20/110
31515101
20
VMU-A 8-40/130
31525101
40
VMU-A 8-55/145
31528101
55
VMU-A 8-70/160
31530101
70
VMU-A 8-115/205
31550101
115
VMU-A 10-10/110
31605101
10
VMU-A 10-30/130
31625101
30
VMU-A 10-50/150
31630101
50
VMU-A 10-65/165
31635101
65
VMU-A 10-90/190
31645101
90
VMU-A 10-160/260
31655101
160
VMU-A 12-10/135
31710101
10
VMU-A 12-30/155
31720101
30
VMU-A 12-50/175
31730101
50
VMU-A 12-85/210
31740101
85
VMU-A 12-125/250
31750101
125
VMU-A 12-175/300
31760101
175
VMU-A 16-15/160
31810101
15
VMU-A 16-30/175
31815101
30
VMU-A 16-60/205
31820101
60
VMU-A 16-90/235
31830101
90
VMU-A 16-155/300
31840101
155
VMU-A 20-50/240
31910101
50
VMU-A 20-70/260
31915101
70
VMU-A 20-95/285
31920101
95
VMU-A 20-115/305
31925101
115
VMU-A 20-160/350
31930101
160
VMU-A 20-210/400
31935101
210
VMU-A 24-55/290
31960101
55
VMU-A 24-115/350
31965101
115
VMU-A 24-165/400
31970101
165
VMU-A 30-70/370
31990101
70
Threaded studs hot dip galvanized on demand


Threaded Studs VMU-A and VMU-AH for the use in masonry
steel, zinc plated/ hot dip galvanized


Description
Ref. No.
steel, zinc plated
Fixture thickness
[mm]
VMU-A 8-10/100
31510101
10
VMU-A 8-20/110
31515101
20
VMU-A 8-40/130
31525101
40
VMU-A 8-55/145
31528101
55
VMU-A 8-70/160
31530101
70
VMU-A 8-115/205
31550101
115
VMU-A 10-10/110
31605101
10
VMU-A 10-30/130
31625101
30
VMU-A 10-50/150
31630101
50
VMU-A 10-65/165
31635101
65
VMU-A 10-90/190
31645101
90
VMU-A 10-160/260
31655101
160
VMU-A 12-15/120*
31717101
15
VMU-A 12-25/130*
31718101
25
VMU-A 12-50/155*
31732101
50
VMU-A 12-80/185*
31734101
80
VMU-A 12-120/225*
31748101
120
VMU-A 12-160/265*
31757101
160
VMU-AH 12-15/120**
31302181
15
VMU-AH 12-25/130**
31304181
25
VMU-AH 12-50/155**
31306181
50
VMU-AH 12-80/185**
31310181
80
VMU-AH 12-120/225**
31312181
120
VMU-AH 12-160/265**
31315181
160
* VMU-A M12: Installation in solid brickwork without perfo-sleeve
** VMU-AH M12: Installation in hollow bricks withs perfo-sleeve



Internally Threaded Sleeves VMU-IG und VMU-IGH for the use in masonry
steel, zinc plated

Description
Ref. No.
steel, zinc plated
Screwing depth
min/max
[mm]
VMU-IG M6
31500101
8 / 20
VMU-IG M8
31560101
8 / 20
VMU-IGH M6
31060111
8 / 20
VMU-IGH M8
31160111
8 / 20


Perfo Sleeve VMU-SH


Description
Ref. No.
Drill hole Ø x Depth
[mm]
VMU-SH 14 x 100
28171301
14 x 105
VMU-SH 16 x 100
28171501
16 x 105



Cartridges VMU
Two-component-cartridge,Vinyl ester styrene free


 

Description
Ref. No.
Content
Cartridge VMU 150
28255261
150 ml
Cartridge VMU 300*

28255140

300 ml
Cartridge VMU 345
28255371
345 ml
Static mixer VM-X

28305111

 
Mixer extension VM-XE
(200mm)

28306111

 
* not part of the approvals


Accessories:

Dispenser:

Dispenser VM-P 345 Standard

Standard dispenser for cartridges of 345,300 and 150 ml,
also suitable for sealant cartridges
Ref.No.:28350505
Dispenser VM-P 345 Profi

Professional quality dispenser for cartridges of 345,300 and 150 ml,
also suitable for sealant cartridges
Ref.No.: 28350511

Blow-out pump:

Description
Ref. No.
For drill holes Ø
[mm]
Blow-out bulp VM-AP

33200101

10-18
Air gun VM ABP
33100101
24-32

Cleaning brushes:



Description
Ref.No.
For drill holes
Ø [mm]
For the use in
RB 10
33408101
10
concrete
RB 12
33410101
12
concrete
RB 14
33412101
14
concrete
RB 18
33416101
18
concrete
RB 22
33418101
22
concrete
RB 26
33424101
26
concrete
RB 32
33432101
32
concrete
RB-H 18
29918501
10-16
masonry




[Loads and performance data]
[Installation parameters]
[Product range]


...a solid connection
 
Metall-Kunststoff-Technik Phone +49 (0) 63 74 / 91 16-0
GmbH & Co.KG Fax +49 (0) 63 74 / 91 16-60
Auf dem Immel 2 info@mkt-duebel.de
D-67685 Weilerbach www.mkt-duebel.de